Loading image...

Radiant Heaters
Warmth, without compromise
Radiant heaters deliver targeted warmth with even heat distribution, with no drafts and no cold spots, creating a quiet, allergy‑friendly ambience indoors and out. Engineered with infrared technology, HEATSCOPE® radiant heaters pair energy‑efficient performance with refined design, offering fast, comfortable heat and lower running costs for contemporary spaces.
Models
Showing 3 items of 3
Spot 2800W Electric Radiant Heater
Vision 3200W Electric Radiant Heater
Pure+ 3000W Electric Radiant Heater
Loading image...

Carbon spiral heating technology
Dual carbon heating spirals power our radiant heaters with reduced visible light and a naturally cosy feel.
Loading image...


Energy‑efficient radiant heaters
HEATSCOPE radiant heaters convert 90–94% of energy into ambient warmth for low running costs and high comfort.
Loading image...

Rapid heat‑up times
Spot radiant heaters reach full output in about 15 seconds; Pure and Vision models ramp quickly owing to the glass‑ceramic front.
Two‑stage output control
Radiant heaters with 50% and 100% output modes via remote or hardwire for precise zone heating and energy optimisation.
Loading image...


Outdoor‑ready IP protection
Pure radiant heaters are IP65 rated for exposed installs; Spot and Vision are IP24 for well‑covered areas.
Styled by Our Clients
Learn More
Radiant Heaters
Outdoor Radiant Heaters
FAQ's
How quickly do HEATSCOPE® outdoor heaters warm up?
HEATSCOPE weather-resistant infrared heaters reach full output in under 15 seconds on most models; the glass-fronted range reaches comfortable warmth in under 60 seconds. You feel the warmth almost the moment the heater switches on, because infrared radiation travels through the air like sunlight and warms people and surfaces directly rather than heating the surrounding atmosphere.
That direct-to-body transfer is why outdoor patio heating with infrared behaves differently from a gas patio heater or a fan heater. There is no lag while the air temperature climbs, and almost no heat loss to wind or open sides of a pergola. Two practical benefits follow:
- Guests arriving to a cold terrace feel warmth within seconds of the heater being switched on, rather than waiting 20 to 30 minutes for air temperature to rise.
- Instant-on, instant-off operation means you only run the heater during occupied moments, keeping energy use close to actual occupancy time.
Carbon fibre elements are rated for at least 10,000 operating hours, and radiant efficiency across the range sits between 87 and 94 percent, so that fast warmth is delivered consistently across years of residential or commercial use.
What is the difference between a radiant heater and a convection heater for outdoor use?
Weather-resistant radiant heaters warm people and surfaces directly through infrared waves, while convection heaters warm the surrounding air, making radiant the practical choice for outdoor use. Air is largely transparent to mid-wave infrared, so the energy travels through open space and is absorbed by skin, tables, floors and nearby objects, much like warmth from the sun on a cool day.
Convection relies on still air to build a pocket of warmth around you. Outside, that pocket drifts away on the first breeze, taking comfort with it.
Heatscope's carbon spiral technology converts up to 94% of its energy into directed infrared heat, so warmth holds its focus even in exposed patios, courtyards and open-fronted venues. Start-up is near-instant, and because there is no flue or ventilation requirement, placement follows the design of the space rather than the other way around.
How do I choose between the Heatscope Spot, Pure, Vision, and Next models?
The Pure Plus suits fully exposed outdoor installations, Vision minimises visible light for sheltered alfresco dining, Next covers semi-open and indoor-outdoor transitions, and Spot provides compact, targeted directional warmth. Weather-resistant requirements are the primary filter.
Pure Plus is the definitive choice for open-air patios, pool surrounds, and unroofed terraces. It carries the highest weatherproof rating in the range (IP65) and uses a convex SCHOTT NEXTREMA glass-ceramic front that spreads sun-like warmth evenly while softening the visible glow.
For covered alfresco rooms, loggias, and sheltered dining zones where atmosphere matters alongside warmth, Vision is the model to consider. Its ceramic glass front reduces visible light to a minimum, creating the most ambient footprint of the range at 3,200W, the highest heat output in the lineup.
Next suits semi-open terraces, verandahs, and spaces that shift between indoor and outdoor use. Its slim aluminium profile fits flush to wall and ceiling surfaces without visual bulk.
Spot concentrates directional infrared on a specific zone, a balcony, a covered nook, or a set of seats, and comes in two output levels to match the space.
Every range includes two-stage output control and a 2-year warranty. ZigBee smart control is available as an optional accessory on most models.
What is two-stage output control on HEATSCOPE® heaters?
Two-stage output control lets weather-resistant HEATSCOPE radiant heaters switch between 100% and 50% power, so you can match heat delivery to conditions without turning the heater off. On a mild evening, 50% output keeps a patio comfortable while roughly halving energy draw; on colder nights, full power delivers the direct infrared warmth the heaters are engineered for.
The two levels are switchable from a wall switch, an included or optional 2-step infrared remote, or, with a WiFi wall switch, a smartphone and voice assistants like Alexa and Google Assistant. One remote can pair with multiple heaters, which is useful across larger covered areas or split zones in a restaurant or bar setting where different sections need different heat levels at once. ZigBee accessories extend this further on select models for motion-triggered or scene-based control.
Because HEATSCOPE heaters draw significant power at full output, the levels are fixed at 50% and 100%; a standard dimmer is not compatible. That fixed step is deliberate. It protects the heating elements and keeps infrared output stable and efficient at both settings.
Can outdoor radiant heaters be used in covered outdoor areas like pergolas?
Yes, weather-resistant outdoor radiant heaters are purpose-built for covered areas like pergolas, and a sheltered structure is the ideal setting for infrared heating. Because the heat travels in a direct beam to warm people and surfaces rather than the surrounding air, a pergola roof helps contain that warmth without the wind dispersion open patios experience.
Pergola installation comes down to clearances and mount choice. Heatscope models accept wall or ceiling mounting across the range, with a minimum 1,800 mm [70.9 in] clearance from the lower edge of the unit to the floor, and 200 mm [7.9 in] from any power source. When the pergola ceiling sits lower than standard, extension rods of 100, 300 or 500 mm drop the heater to the correct height. Timber pergolas are fine with Heatscope spacers, which maintain the recommended distance from combustible material. Installation must follow local electrical wiring standards and be carried out by a licensed electrician, connected through a residual current device (RCD).
Is radiant heating suitable for all room types?
Radiant heating is suitable for most room types, with a few environment-specific exceptions to guide installation decisions.
Heatscope radiant heaters work well in living areas, dining rooms, bedrooms, kitchens, bathrooms, hallways, and open-plan spaces. The infrared heat carries through air without relying on ventilation or air circulation, making it particularly effective in enclosed, draught-prone, or high-ceiling rooms where forced-air systems underperform. Heat reaches occupants directly rather than dissipating overhead.
Environments where standard installation is not appropriate:
German-engineered and Red Dot Design Award winning, Heatscope heaters are tested rigorously across climates. The technology's independence from ducting and gas lines lets it adapt to any room geometry without constraining architecture.
Which HEATSCOPE® radiant heater is best for my space?
The best HEATSCOPE radiant heater for your space depends on three practical factors: the location's exposure to weather, the size of the zone you're heating, and your aesthetic preference.
If your space is fully exposed to outdoor elements, such as a rooftop, deck, or open patio, the Pure Plus model's IP65 rating and all-weather design make it the most resilient choice. For semi-covered areas like sheltered patios or balconies, the Spot delivers compact, rapid heat-up (under 15 seconds) across an 8 m² zone, or choose the Vision for larger spaces needing 11 m² coverage with minimal light output from the ceramic glass front.
Consider how you experience the space. The Spot and Vision both offer IP24 weather protection, whilst the Spot's smaller form factor suits intimate areas and the Vision's 1,661 mm width creates a more substantial focal point. All three operate at dual 50/100% power settings and deliver heat in 15-60 seconds depending on the model.
Discuss your specific location, intended installation position, and aesthetic priorities with our specialists, who will recommend which model aligns with your project needs.
How much does it cost to run a HEATSCOPE® outdoor heater per hour?
Running a weather-resistant HEATSCOPE outdoor radiant heater costs roughly the heater's wattage divided by 1,000, multiplied by your local electricity rate per kWh. A 3,000 W heater run for one hour uses 3 kWh, so at an illustrative rate of $0.20/kWh it costs about $0.60 per hour to run.
Per-hour figures across the range, at the same illustrative $0.20/kWh rate:
- 1,600 W compact heater: $0.32/hour at full output, $0.16/hour at 50%
- 2,800 W heater: $0.56/hour at full output, $0.28/hour at 50%
- 3,000 W heater: $0.60/hour at full output, $0.30/hour at 50%
- 3,200 W heater: $0.64/hour at full output, $0.32/hour at 50%
Actual cost depends on your local electricity rate, so replace the illustrative figure with your own tariff for an accurate calculation. A two-hour session at full output on a 3,000 W heater sits near $1.20 at that rate; running the same session at the 50% setting drops the cost to around $0.60.
Mid-wave infrared technology converts up to 94% of energy directly into directed warmth, with minimal energy lost to air or wind dispersion. That efficiency, combined with permanent outdoor installation and weather-resistant construction, is what keeps the cost per comfortable hour low across patios, terraces, and hospitality settings.
Can outdoor radiant heaters be used in the rain?
Yes, Heatscope radiant heaters can be used in the rain, though suitability depends on your model's weather protection rating. Our heaters are engineered with IP ratings that specify their water-resistance capability, allowing us to rate them for different outdoor conditions.
Our highest-rating models carry IP65 certification, meaning full protection against dust and direct water jet spray, suitable for fully exposed outdoor installations without shelter. Other models in our range achieve IP25 to IP24 ratings, which provide splash-water protection and work best in partially covered areas such as patios with an overhang or pergola.
Beyond the IP rating, installation technique enhances durability. A slight downward mounting angle helps water run clear of electrical components. Positioning the heater under an eave or pergola extends the usable season, even for splash-rated models, letting you heat covered outdoor spaces across rainy months. All Heatscope heaters undergo rigorous German engineering testing protocols that validate weather performance. Check your specific model's IP rating when selecting an installation location to ensure the right match for your space's exposure.
What does the IP rating on a radiant heater mean, and why does it matter for outdoor use?
An IP rating certifies how effectively a radiant heater sustains direct heat transfer over its service life by specifying the sealed housing's resistance to solid intrusion and water. Defined by international standard IEC 60529, the code uses two digits: the first (0-6) grades protection against solids, from stray objects through to fine dust; the second (0-9) grades protection against water, from vertical drips through to pressurised jets. For outdoor use, both digits carry real weight.
The water digit gets most of the attention, but the solid digit is what determines how the heater copes with airborne dust, pollen, salt spray and fine grit, precisely the particles that settle on electrical components in coastal, windy or bushfire-prone sites. A higher first digit protects the heating element and internal wiring from the kind of gradual ingress that shortens service life long before water does.
HEATSCOPE ranges span IP24 to IP65, so the relevant question is not whether a heater is 'outdoor rated' but which pairing of digits suits the specific exposure. Matching the rating to the site protects performance, warranty validity, and the consistent direct heat transfer the infrared element is engineered to deliver.
















